SCA Series Air-Cooled Chiller

Fan-cooled chillers for mold cooling and general process cooling. R410A refrigerant, built-in pump and tank, no cooling tower required.

  • Safety assurance with over-temperature design
  • Robust performance with high-quality engineering
  • Simple operation with ergo-design concept
  • Powerful function for displaying settings and return media temperature
ModelCooling Capacity (kW)Cooling Power (kcal/h)Refrigeration (US ton)Total Power (kW)Pump Power (kW)Compressor Power (kW)Flow Rate (L/min)Connector SizeCooling Pressure (bar)Fan Power (kW)MediaWeight (kg)PowerEnquire
SCA03E8.3972152.382.90.372.251001”1.2 - 20.28R410A130220V/60Hz
SCA05E13.95119973.974.660.553.751661-1/2”1.2 - 20.36R410A170220V/60Hz
View SCA Series Air-Cooled Chiller details
XAC Series Air-Cooled Chiller

Packaged air-cooled chiller with integral pump and tank. Rated in tons of refrigeration for mold cooling duty.

ModelRefrigeration CapacityEnquire
XAC 5A4 ton
View XAC Series Air-Cooled Chiller details
XWC-A Air-Cooled Chiller

The XWC-A Air Cooled Chiller features a microcomputer control panel with PID digital temperature setting and display, as well as maximum and minimum temperature control delay protection. Its high efficiency shell and tube condenser and evaporator ensure excellent conductivity and long service life, while the USUNHOME/SANYO or French Mayurle/Bafoma compressor provide safety protection, low noise, power saving, and durability. The chiller also has high and low voltage safety protection switches, overload protection, over temperature safety protection, and antifreeze protection switch. It is ideal for cooling molds to reduce product forming cycles and maintaining equipment at normal temperatures, as well as for other industrial areas that require cooling.

View XWC-A Air-Cooled Chiller details
Water-Cooled Chiller

Shell-and-tube water-cooled chiller for plants already running a cooling tower. Higher efficiency and quieter operation than an equivalent air-cooled unit, with the heat rejected to the tower loop.

View Water-Cooled Chiller details
SINDON Chillers

Effective cooling solutions sized to the press and mold.

View SINDON Chillers details
HIGHSUN Water-Cooled Chiller

Water-cooled industrial chillers for mould and process cooling, from 9.6 to 290 kW of cooling capacity. Shell-and-tube evaporator, R-407C refrigerant and a built-in chilled-water pump from 2 HP, in a compact CNC-built cabinet.

  • Shell-and-tube evaporator: the refrigerant flows through the tubes while the process water circulates through the shell and is cooled. It handles high industrial loads efficiently.
  • High-efficiency threaded copper tubes for fast heat transfer in a small footprint.
  • R-407C refrigerant.
  • Built-in water pump from 2 HP up to 20 HP.
  • CAD/CAM design and CNC machining for a compact, reliable and energy-efficient unit.
  • Capillary throttling up to the ATC-20W; thermal expansion valve from the ATC-24W.
ModelNominal cooling capacity (kW)Nominal cooling capacity (kcal/h)Nominal cooling capacity (Btu/h)Compressor power (kW)RefrigerantThrottleCondenserCooling water flow (L/min)Cooling water connection (DN / in)EvaporatorTank volume (L)Built-in water pump (HP)Chilled water flow (L/min)Chilled water connection (DN / in)Power supply (V)Weight (kg)Dimensions (L × W × H) (mm)Enquire
ATC-3W9.598,24732,7422.2R-407CCapillaryWater-cooled, tank type3625 / 1"Shell-and-tube602600.5"220 / 4401251000 × 600 × 1010
ATC-5W14.512,47049,5063.8R-407CCapillaryWater-cooled, tank type4025 / 1"Shell-and-tube802600.5"220 / 4401451000 × 600 × 1010
ATC-8W22.719,52277,5025.5R-407CCapillaryWater-cooled, tank type8040 / 1.5"Shell-and-tube180212040 / 1.5"220 / 4402201300 × 680 × 1400
ATC-10W2924,94099,0127.5R-407CCapillaryWater-cooled, tank type12040 / 1.5"Shell-and-tube180312040 / 1.5"220 / 4403101300 × 680 × 1400
ATC-15W43.537,500148,87410.8R-407CCapillaryWater-cooled, tank type16050 / 2"Shell-and-tube310318050 / 2"220 / 4405501620 × 750 × 1400
ATC-20W6555,900221,92315R-407CCapillaryWater-cooled, tank type23065 / 2.5"Shell-and-tube420530050 / 2"220 / 4406501900 × 900 × 1600
ATC-24W7667,380267,49919R-407CThermal expansion valveWater-cooled, tank type28080 / 3"Shell-and-tube500538065 / 2.5"220 / 4407501900 × 900 × 1600
ATC-60W189150,000643,23545R-407CThermal expansion valveWater-cooled, tank type750125 / 5"Shell-and-tube92010850125 / 5"220 / 44015002450 × 1000 × 1650
ATC-72W22618,000756,12154R-407CThermal expansion valveWater-cooled, tank type860150 / 6"Shell-and-tube110015960150 / 6"220 / 44016002200 × 1200 × 1900
ATC-100W290249,400990,12075R-407CThermal expansion valveWater-cooled, tank type1100200 / 8"Shell-and-tube1300201200200 / 8"220 / 44019002650 × 1050 × 1750
View HIGHSUN Water-Cooled Chiller details
HIGHSUN Air-Cooled Chiller

Air-cooled industrial chillers from 8.4 to 147 kW. A tube-and-fin condenser with low-noise axial fans rejects heat straight to the air, so no cooling tower is needed. Ideal where water is scarce or hard.

  • Tube-and-fin condenser: copper tubes carry the refrigerant while metal fins and the air flow dissipate its heat faster.
  • Shell-and-tube evaporator: the refrigerant flows through the tubes while the process water circulates through the shell and is cooled. It handles high industrial loads efficiently.
  • R-407C refrigerant.
  • Built-in water pump from 2 HP up to 10 HP.
  • Imported copper tube, secondary-flanged fins and automatic elbow welding: close tube-to-fin contact and a leak-free refrigerant circuit.
  • Capillary throttling up to the ATC-20A; thermal expansion valve from the ATC-24A.
ModelNominal cooling capacity (kW)Nominal cooling capacity (kcal/h)Nominal cooling capacity (Btu/h)Compressor power (kW)RefrigerantThrottleCondenserEvaporatorTank volume (L)Built-in water pump (HP)Water connection (DN / in)Power supply (V)Weight (kg)Dimensions (L × W × H) (mm)Enquire
ATC-3A8.367,18828,5452.2R-407CCapillaryTube-and-fin, low-noise axial fanShell-and-tube60220 / 0.75"220 / 4401351000 × 600 × 1010
ATC-5A10.679,17536,4283.8R-407CCapillaryTube-and-fin, low-noise axial fanShell-and-tube80220 / 0.75"220 / 4401761000 × 600 × 1010
ATC-8A21.8118,75074,4385.5R-407CCapillaryTube-and-fin, low-noise axial fanShell-and-tube180240 / 1.5"220 / 4403201300 × 680 × 1400
ATC-10A2622,36088,7697.5R-407CCapillaryTube-and-fin, low-noise axial fanShell-and-tube180340 / 1.5"220 / 4404101300 × 680 × 1400
ATC-15A40.334,658137,59210.8R-407CCapillaryTube-and-fin, low-noise axial fanShell-and-tube280350 / 2"220 / 4407101620 × 750 × 1400
ATC-20A5850,000198,50015R-407CCapillaryTube-and-fin, low-noise axial fanShell-and-tube410565 / 2.5"220 / 4408301900 × 900 × 1600
ATC-24A7161,060242,40819R-407CThermal expansion valveTube-and-fin, low-noise axial fanShell-and-tube410580 / 3"220 / 4409901900 × 900 × 1600
ATC-30A8068,800273,13622R-407CThermal expansion valveTube-and-fin, low-noise axial fanShell-and-tube6107.580 / 3"220 / 44014002450 × 1000 × 1650
ATC-40A120101,500422,73233R-407CThermal expansion valveTube-and-fin, low-noise axial fanShell-and-tube8001080 / 3"220 / 44016002200 × 1200 × 1900
ATC-50A147124,327515,52139.8R-407CThermal expansion valveTube-and-fin, low-noise axial fanShell-and-tube8001080 / 3"220 / 44018002650 × 1050 × 1750
View HIGHSUN Air-Cooled Chiller details